U.S. Access Board A Summary of Accessibility Guidelines for Play Areas Page 27 Handrails Handrails are required on both sides of ramps connecting elevated play components. Handrails must comply with the following: • Clearance between handrail gripping surfaces and adjacent surfaces and shall not be 1 1/2 inches (38mm) minimum. • Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides. The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length. Where provided, horizontal projections shall occur 1 1/2 inches (38mm) minimum below the bottom of the handrail gripping surface. In this case, additional handrails have been provided. Handrails are required to comply with ADA/ABA 505. However, extensions on handrails in the play area are not required. This is to prevent children running into protruding rails in the play area. 45 what are the requirements for accessible routes?