Step 4: Visually determine if the projection extends beyond the face of the slide projection gauge. Pass: A projection that does not extend beyond the face of the gauge passes. Fail: A projection that extends beyond the face of the gauge is considered a hazardous protrusion and should be eliminated. NOTE: This test procedure is not applicable to the underside of a slide chute. For a slide chute with a circular cross section, the portion of the underside not subject to this projection recommendation is shown in Figure 18. The general recommendations for projections in §B.2.1 are applicable to the underside of the slide. Handbook for Public Playground Safety 50 SLIDING SURFACE 21" R 21" R 42" 19" Toddlers/ 14" Preschool/School SHADED AREA REPRESENTS NON-ENTANGLEMENT/PROTRUSION ZONES EXIT SECTION SIDEWALL 60" STANDING HEIGHT 21" R PERPENDICULAR SURFACE 1/8 Inch maximum Figure B13. Recommended areas to test for slide entanglement protrusions HORIZONTAL PLANE 1/8 inch maximum Figure B12. Upward facing projection